Method & Line | Sample & Target | Product | Package Info | Product | Package Info |
---|---|---|---|---|---|
MicroELISA | Plasma,Serum | EIAgen Total T4 Kit | Tests per Package: 96 | ||
EIAgen | EIAgen Total T4 Kit is a direct solid phase enzyme immunoassay for the quantitative determination of total Thyroxine (T4) in human serum or plasma. The method can be used to measure T4 concentrations over the range of 4 to 300 ng/mL ( 0.4 to 30 µg/dL). | Code: LI4020 | Package: 1 Microplate |
For Quantity Orders: Request a Quote
Please pay attention to the revision of the document that must be the same as the revision reported in the box label.
In case of discrepancy please contact our Customer Care e-mail: info@adaltis.net.
* Other document related to the product available at Documentation Centre and it is accessible for Adaltis distributors/partners after registration only.
EIAgen Total T4 Kit is a direct solid phase enzyme immunoassay for the quantitative determination of total Thyroxine (T4) in human serum or plasma. The method can be used to measure T4 concentrations over the range of 4 to 300 ng/mL (0.4 to 30 µg/dL).
Measurement of serum thyroxine concentration is generally regarded as an important in-vitro diagnostic test for assessing thyroid function. This importance has provided the impetus for the significant improvement in assay methodology that has occurred in the last three decades. This procedural evolution can be traced from the empirical protein bound iodine (PBI) test (1) to the theoretically sophisticated radioimmunoassay (2).
This microplate enzyme immunoassay methodology provides the technician with optimum sensitivity while requiring few technical manipulations.
Sample of serum or plasma is pipetted into the well coated with Streptavidin. The addition of the Biotin-T4 conjugate (Biotin-T4) and of the immunological reaction starter Anti-T4 -HRP conjugate initiates the competitive assay. During the immunological incubation, the T4 of the sample competes with the Biotin-T4 conjugate for the anti-T4 binding sites of the HRP Anti T4 conjugate which, in turn, is bound by the streptavidin coated wells through the biotin moiety. After washing off the non-reacted species, the amount of the immunological complex remained bound to the wells
Streptavidin : Biotin-T4 : Anti-T4-HRP
is revealed by the incubation with the chromogen/substrate. The blue colour development is then stopped with sulphuric acid, turning the final solution to a yellow colour which is measured photometrically at 450 nm. The intensity of the colour is proportional to the bound HRP-T4 conjugate, and therefore inversely related to the amount of T4 in the sample.
By reference to a series of T4 calibrators, assayed in the same way, the concentration of T4 in the unknown sample is quantified.
Each kit contains sufficient reagents to perform 96 tests (code LI4020).
Bring reagents to room temperature before use.
StreptavidinMicroplate Calibrators Conjugate T4-Biotin Conjugate Substrate TMB Stop Solution Wash Buffer Conc. 10x Adhesive Films |
1 6x1 mL/vials 1x8 mL/vial 1x8 mL/vial 1x16 mL/vial 1x15 mL/vial 1x50 mL/vial 2 |
Number of tests |
96 |
Code |
LI4020 |
Need assistance to make an order? Contact Sales & Orders Centre order@adaltis.net.
For Application Support application@adaltis.net